NACOL_E_2024_04
7/130

×〇××〇×〇××61. Fasten the accumulator with plural clamps.2. Fix the accumulator and the hydraulic piping on the same stand which has sufficient rigidity.3. When fixing the accumulator on the stand, pay attention to the mounting method of clamps.· If there is an interspace between the accumulator and the stand, do not fill the gap forcibly by clamps and fix it. Fill the interspace with spacers etc., and be careful not to apply excessive force. If the gap is forced out and it is fixed, load may be applied to the piping part or the oil port valve, and it may become the cause of failure or leakage.· The accumulator shall be fastened properly with plural clamps. Applying excessive force may cause damage or leakage.· If the accumulator moves or vibrates in the different directions to the piping, the load may be applied to the piping and/or the oil port valve, and they may be damaged. Use the stand which has sufficient load bearing capacity and rigidity.The accumulator is installed from the position that interspace exists at the back.No GoodFix with One ClampNo GoodVibration of StandVibrations of Accumulator and Piping are differentPut in the spacers of the same size as interspace and be careful not to apply excessive force at the time of accumulator tightening.Vibration of PipingAccumulator and Piping are on the same vibrationGoodGoodFix with Plural ClampsGoodNo GoodExcessive force is applied to oil port valve etc., when accumulator is tightened without putting in the spacers.Warning for Accumulator Installation○○○○○○