〇××××7×No GoodIntroductionSeveral Advices for CustomersIf there is no appropriate interspace between the accumulator and the stand, do not push the accumulator to the stand by force, but redo construction. If it is fixed by force, load may be applied to the piping part or the oil port valve, and it may become the cause of failure or leakage.Periodically confirm the tightness of the clamps, the ring nut, and the fixing tools for pipes and tighten them.When the back space of accumulator is not constant.Excessive force is applied to oil port valve etc., if flange connection is done in the condition that the accumulator is pushed to the stand.GoodBy putting in the spacers which are in accord with interspace, excessive force is not applied to the accumulator.The accumulator has leaned.The center of clamps has shifted.By tightening of clamps, the bending moment generates in oil port valve etc.No GoodExcessive force is applied to oil port valve etc., when accumulator is tightened with the spacers which are not in accord with interspace.○○○○○○